AU680 Clinical Chemistry Analyzer
Meet ever-increasing pressures on time and productivity with ease. The AU680 clinical chemistry analyzer gives mid- to high-volume laboratories the flexibility to improve efficiencies and economics their way. Operate the AU680 as a standalone system or connect it to laboratory automation and IT solutions. With throughput of up to 800 photometric tests per hour (up to 1,200 with ISEs) and 63 onboard parameters, the AU680 clinical chemistry analyzer delivers field-proven reliability and efficiency to laboratories around the world.
Analytical System |
Fully automated, random-access clinical chemistry system with STAT capability |
Analytical Principles |
Spectrophotometry and potentiometry |
Analytical Types |
Endpoint, rate, fixed point and indirect ISE |
Analytical Methods |
Colorimetry, turbidimetry, latex agglutination, homogeneous EIA, indirect ISE |
Simultaneously Processed Analytes |
60 photometric tests + 3 ISE |
Throughput |
800 photometric tests/hour; up to 1,200 with ISE |
Sample Types |
Serum, plasma, urine, whole blood (HbA1c) and other fluids |
Sample Feeder |
Racks with 10 samples each (barcodes on primary tubes and on racks); capacity of 150 samples; continuous loading |
Sample Tubes |
In primary and secondary tubes; diameter between 11.5 and 16.5 mm; height between 55 and 102 mm |
STAT Samples |
Up to 22 positions for STAT samples, barcoded primary tubes |
Sample Volume |
1–25 μL in 0.1 μL increments (1–25 μL for repeats) |
Reagent Supply |
60 positions for R1, 48 positions for R2; refrigerated: 4–12°C; handling of 3-shot reagents |
Reagent Volume |
R1: 15–250 μL; R2: 15–250 μL; in 1 μL increments |
Total Reaction Volume |
120–425 μL |
Reaction Cuvette |
Quartz cuvettes |
Reaction Time |
Up to 8 minutes, 40 seconds |
Reaction Temperature |
37°C |
Mixing Method |
With rotating paddles after dispensing sample and reagent |
Photometry System |
Direct assay through the reaction cuvette (0–3.0 OD) mono and bichromatic measurements possible |
Wavelength |
13 different wavelengths between 340–800 nm |
Cuvette Cleaning |
Comprehensive cleaning with detergents |
Calibration |
Autocalibration, cooled calibrator positions; master calibration established by two-dimensional barcode on the reagent bottle (>3-point calibration) |
Quality Control |
Auto QC, cooled QC positions |
Test Requisition |
Individual and profile test requisition via online, mouse, function keys or touch screen |
Safety |
Clot detection and crash prevention for sample and reagent dispenser |
Online |
Full uni- and bi-directional communication possible |
Software |
Windows 7® |
Data Storage |
Sample number: 100,000 samples. Reaction data: 200,000 tests. |
Dimensions (WxHxD) |
ANL 1,950x1,280x1,000 |
Power Supply |
200 V; 208 V; 220 V; 230 V; 240 V; 50 Hz; 60 Hz/3.8 KVA |
We offer product training courses and guides to give you the skills and knowledge you need to operate your clinical laboratory instruments.
See all product training courses and guides ›
Tips & Tools
- AU680 Chemistry Analyzer
- AU680 Daily Start Up Job Aid (DTS)
- AU680 Daily Start Up Job Aid (PE-DTS)
- AU680 Daily Startup with Prower Processor
- AU680 Daily Startup
- AU680 Every Other Week and Weekly Maintenance Job Aid
- AU680 Every Other Week Efficiency Job Aids
- AU680 Job Aid Booklet
- AU680 Monthly Efficiency Job Aids
- AU680 Monthly Maintenance
- AU680 Quick Start Guide
- AU680 Sample Processing Overview
- AU680 Software Overview
- AU680 Systematic Approach to Troubleshooting
- AU680 In-Lab Training Manual
- AU680 New Test Configuration
- AU680 Competency Checklist
- AU480 680 Reagent Consumption Job Aid
- AU480 680 Sample Racks and Containers
- AU & DxC Diazyme Procalcitonin Customer Installation Guidelines
- AU Calculated Parameter Configuration
- AU Routine Cleaning Solutions
- AU Troubleshooting Tips