We offer product training courses and guides to give you the skills and knowledge you need to operate your clinical laboratory instruments.
See all product training courses and guides ›
AutoMate 2500 Family Sample Processing Systems
When you need to improve efficiency, turn to the AutoMate 2500 family of sample processing systems. The AutoMate 2500 family features Intelligent Sample Banking (ISB) software to deliver an automation system that fits your laboratory’s unique needs. The AutoMate family of sample processing systems allows you to streamline pre- and post-analytical processes to help you gain optimal performance and use of resources, eliminating steps between sample receipt and analysis. ISB enhances your automated solution by enabling you to build and manage a sample bank with maximum efficiency and security and increased control over sample traceability.
Case Study Lower Costs and Simplify Workflow
Discover how a leading university hospital laboratory was able to simplify workflow and help prevent operator confusion and mistakes with the AutoMate 2550.
DownloadAdvanced capabilities
- Minimize manual handling with automated sample loading and sorting
- Simplify measuring with through-the-label sample volume detection
- Enable fast processing with sorting speeds of 800–1,200 tubes per hour
- Reduce manual sample preparation errors and ensure faster, more accurate secondary tube preparation with intelligent aliquoting* and tube labeling
- Experience ease of use with intuitive software
- Transfer sample to archiving safely and conveniently with recapper technology
Single point of entry
- Manage sample tubes from entry into the laboratory until archiving
- Re-sort samples for pending test routing or for storage when samples have volume remaining
- Sort STATs to separate locations
- Provide sorting flexibility with up to 24 dynamically configurable rack locations
- Unload and load instrument-specific racks
Tube inspection unit cap color recognition
- Validate sample type against test ordered to prevent errors with cap color analysis
- Detect the newest generation of coded caps
Volume determination
- Gain better sample control with automated measurement of each sample’s volume prior to dispensing into aliquot tube or for storage
- Ascertain whether all aliquots can be created through automated measurement of plasma or serum volume
- Allow infrared volume detection of up to three layers of labels on the tube with read-through labels
Aliquoting*
- Process up to 900 total samples per hour
- Create up to seven aliquots per primary tube
- Measure filling level accurately through conductive tips with graphite fraction
- Transfer the proper volume for samples with single or multiple tests
- Prioritize aliquots to ensure most critical samples are created first, if sample volume is minimal
- Detect clots and route clotted samples for manual processing
Sorting to sample racks
- Sort to generic 50-tube racks or analyzer racks to accommodate transfers to instruments, other laboratory sections or send-out test requirements through an open system architecture
- Create up to 150 sorting locations by subdividing 1,200-sample capacity and up to 24 generic racks
- Freely define and dynamically configure drawers; select the standard 50-position rack or instrument-specific racks
- Re-sort samples from personality racks after analysis, either to next analyzer or sample storage; determine routing by duration or user-defined destination
Case Study More Ways to Increase Effectiveness
Find out how one laboratory reduced sample processing times and increased laboratory effectiveness with the AutoMate 1250 system.
DownloadBrochure Automation that Fits
Discover how the AutoMate system streamlines pre- and post-analytical processes to speed test results and create greater workflow efficiencies in the laboratory.
DownloadBrochure Clinical Laboratory Automation: Intelligent Sample Banking
Learn about the importance of sample bank processing and how one laboratory gained greater traceability with ISB software.
Download
Throughput |
Sorting Rate:
Aliquotter*(1+1 aliquot):
|
Sample Container Sizes |
Processes tube sizes from 10.5-17 mm in diameter; 70-110 mm in height (with cap) |
Environmental Requirements |
Heat Output:
Room Temperature: 18-32°C (64-89°F) Relative Humidity: 40-80% non-condensing |
LIS Integration |
LIS Interface: Dynamic download or host query |
Weight |
|
Tips & Tools
Select Tips & Tools to access helpful documents and information for your instrument.
Step 1: To access content such as job aids, checklists, In-Lab Training Manuals, etc., select the Tips & Tools link in the top left navigation
Step 2: Select the product name.
Step 3: You will be directed to the product page and access to the product-specific content.
Click here to access Tips & Tools
The system provided by Beckman Coulter is not operator-dependent. Risks associated with aliquoting and patient demographics are eliminated because the processing and data transfer is fully automated.